Galvalume Metal Roofing Sri

By | October 27, 2011

1297-076100-Sheet Metal Roofing
B. Roof Surface: Minimum solar reflectance (SRI) of 29, calculated in accordance with ASTM E1980. 1. Reflectance: corrugated plastic venting baffle with Galvalume metal cap to match roofing panels. Provide min. 17 sq. in. per foot NFVA. 2.05 FABRICATION … Read More

Why Is Cool Metal Roofing Important? – Eco-$mart – One Stop …
Cool Metal Roofing and Energy Star “Use roofing materials having a Solar Reflectance Index (SRI) equal to or greater than the values in the table below for a minimum of 75% of the roof surface.” What Qualifies ? … View Document

BERRIDGE MANUFACTURING COMPANY
Berridge metal roofing can help reduce energy consumption by lowering cooling loads. The reflective materials used in our roofs emissivity and solar reflectance index (SRI) of Berridge metal roofing helps mitigate the heat island effect. … Content Retrieval

High Performance Metal Roofing Finishes
Metal Roofing Finishes To Order Call Toll Free: (888).321.9630 Stone White SR.66/TE.87 Colonial Red SR.26/TE.87 Slate Blue SR.35/TE.87 Forest Green SR.28/TE.87 Dove Gray *Solar Reflectance Index (SRI) © 2012 Drexel Metals Inc. All rights reserved. … View This Document

SIGNATURE 200 Cool Colors Selection Chart Solar Reflectivity …
Solar Reflectance Index (SRI)? The SRI is used to determine compliance with LEED requirements and is calculated according to ASTM E 1980 metal roofing, siding, louvers, fascia, appliedcurtain wall, spandrel paneling and arecolumn covers. … Fetch Here

An Evaluation Of Chemically Treated 55% Al-Zn Alloy Coated …
Steel Roofing Material to Determine Whether it Meets the Requirements of As part of a research project to assess the long-term durability and energy efficiency of their metal roofing systems, the Galvalume Sheet Producers of North America have teamed with the Oak Ridge … Read More

Metals Trade Associations
Metal Roofing Alliance. Metal Treating Institute (MTI) Metallurgical Society of Canada (MetSoc) Metals Service Center Institute (MSCI) Steel Recycling Institute (SRI) Steel Shipping Container Institute (SSCI) Steel Stud Manufacturers Association (SSMA) … Read Article

YOUR METAL CONSTRUCTION SOLUTION COMMERCIAL / INDUSTRIAL …
For complete performance specifications, product limitations and disclaimers, please consult Metal Depots Paint and Galvalume Plus roofing and an SRI value of 78 or higher for low slope (2:12 or less) roofing. For more information, please go to www.usgbc.org. What is … Get Document

The Basics Of Standing Seam Metal Roofs – Home Renovation …
The hottest, newest roofing material is called the standing seam metal roof. Is it right for your house? … Read Article

Heat Island Effect:Roof – Metal Construction Association …
Heat Island Effect:Roof: Solar Reflective Index (SRI) Calculator (rev 4-11-07) May 12, 2006 Cool Greetings, Cool Metal Roofing Coalition 680 Andersen Drive Pittsburgh, PA 15220 412-922-2772 ext 206 412-922-3213 fax gcrawford@steel.org … Access Document

CMP Energy Star – Metal Roofing Panels | Solar Panel Roof …
Acrylic Galvalume* 0.68 55 * = Available in 26 gauge material. SRI= Solar Reflectance Index. Note: requirements of LEED, a roofing material needs to have an SRI at 29 or greater for steep slope roofing applications and an SRI value at 78 or … Read Content

Millennium 3000 Paint System – American Building Components …
Please call ABC for a metal color chip to verify color selection. Please inquire for additional color availability, pricing and lead-times. GALVALUME PLUS® SR .68 SRI 56 SADDLE TAN SR .48 SRI 56 KOKO BROWN RUSTIC RED SR .28 SRI 29 SR .36 SRI 40 REGAL WHITE SR .52 SRI 61 IVY GREEN … Fetch Document

SRI RAMANA ENTERPRISES – YouTube
We will supply any metal sheet Matching Profile in Polycarbonate Sheet. We are providing entire roofing materials in one roof. Category Science & Technology. License. Standard YouTube License Show more . Show less . Loading … View Video

Polar White Is A Straight Polyester. STAndARd COLORS 26-GAUGE …
SOLAR REfLECTANCE INDEx (SRI)? The SRI is used to determine compliance with 2:12) roofing and an SRI value of 78 or higher for low slope (2:12 or less) roofing. For more information, please go to www.usgbc.org. SOLAR REfLECTIvITy (SR)? … Fetch Doc

8600 South I-35 Cool Standard Colors
What is Solar Reflectance Index (SRI)? The SRI is used to determine compliance with LEED requirements and metal roofing, siding, louvers, fascia, curtain wall, appliedspandrel paneling and column covers. TThe building components can be post-formed … Access Full Source

Cool Metal Roofing Coalition Letter – Home : ENERGY STAR
The Cool Metal Roofing Coalition wishes to compliment EPA on its Final Draft ENERGY STAR specification TE SRI(i) SRI(a) Mill passivated Galvalume 0.78 0.58 0.08 yields 75 34 Acrylic coated Galvalume 0.68 0.55 0.08 yields 55 28 As shown … Retrieve Doc

FOR GALVALUME – Home | Affordable Metal Manufacturing
High performance metal roofing coils are available in Galvalume *Solar Reflectance Index (SRI) Colors shown represent the actual color as closely as possible. To ensure exact color for final approval, a metal color chip is available. … Retrieve Document

– A A
Metal Color Insert 6/11 –M#EM26-0004 Duro-Last is a registered mark owned by Duro-Last Roofing, Inc. ENERGY STAR is only valid in the United States. Duro-Last is proudly manufactured in the * Solar Reflectance Index (SRI) Title: … Get Content Here

Cool Metal Roofing
roofing products or coatings used specifically in the metal roofing industry. The Cool Roof Rating Council (CRRC) was established in 1998 as a non-profit Heat Island Effect: Roof Roof Type Slope SRI (minimum) Low-Sloped Roof ≤ 2:12 78 … Retrieve Doc

Expectation Of metal roofing Reflected In LEED Version 2
Expectation of metal roofing reflected in LEED version 2.2 By Kevin Corcoran and Gene Johnson he architectural community must meet a solar reflectance index, or SRI, of 78 while steep-sloped roofs with a slope of more than 2:12 must have an SRI of 29. … Return Document

Leave a Reply

Your email address will not be published. Required fields are marked *